dinsdag 1 januari 2013

Packet tracer E3.4.4.2.2



PC1
ip        172.17.10.1
subnet 255.255.255.0

PC2
ip        172.17.20.1
subnet 255.255.255.0

PC3
ip        172.17.30.1
subnet 255.255.255.0

PC4
ip        172.17.10.2
subnet 255.255.255.0

PC5
ip        172.17.20.2
subnet 255.255.255.0

PC6
ip        172.17.30.2
subnet 255.255.255.0

S1 vlan 99
ip        172.17.99.11
subnet 255.255.255.0

S2 vlan 99
ip        172.17.99.12
subnet 255.255.255.0

S3 vlan 99
ip        172.17.99.13
subnet 255.255.255.0

S1:
Switch>en
Switch#conf t
Switch(config)#hostname S1
S1(config)#vlan 99
S1(config-vlan)#name management
S1(config-vlan)#vlan 10
S1(config-vlan)#name engineering
S1(config-vlan)#vlan 20
S1(config-vlan)#name sales
S1(config-vlan)#vlan 30
S1(config-vlan)#name administration
S1(config-vlan)#exit
S1(config)#no ip domain-lookup
S1(config)#enable secret class
S1(config)#line con 0
S1(config-line)#password cisco
S1(config-line)#login
S1(config-line)#exit
S1(config)# exit
S1#vlan database
S1(vlan)#vtp domain access
S1(vlan)#vtp password lab4
S1(vlan)#exit
S1#conf t
S1(config)#int fa0/11
S1(config-if)#switchport access vlan 10
S1(config-if)#no shut
S1(config-if)#int fa0/18
S1(config-if)#switchport access vlan 20
S1(config-if)#no shut
S1(config-if)#int fa0/6
S1(config-if)#switchport access vlan 30
S1(config-if)#no shut
S1(config-if)#int vlan 99
S1(config-if)#ip address 172.17.99.11 255.255.255.0
S1(config-if)#int fa0/1
S1(config-if)#switchport trunk native vlan 99
S1(config-if)#switchport mode trunk
S1(config-if)#no shut
S1(config-if)#int fa0/2
S1(config-if)#switchport trunk native vlan 99
S1(config-if)#switchport mode trunk
S1(config-if)#no shut
S1(config-if)#int fa0/3
S1(config-if)#switchport trunk native vlan 99
S1(config-if)#switchport mode trunk
S1(config-if)#no shut
S1(config-if)#int fa0/4
S1(config-if)#switchport trunk native vlan 99
S1(config-if)#switchport mode trunk
S1(config-if)#no shut
S1(config-if)#int fa0/5
S1(config-if)#switchport trunk native vlan 99
S1(config-if)#switchport mode trunk
S1(config-if)#no shut

S2
Switch>en
Switch#conf t
Switch(config)#hostname S2
S2(config)#vlan 99
S2(config-vlan)#name management
S2(config-vlan)#vlan 10
S2(config-vlan)#name engineering
S2(config-vlan)#vlan 20
S2(config-vlan)#name sales
S2(config-vlan)#vlan 30
S2(config-vlan)#name administration
S2(config-vlan)#exit
S2(config)#enable secret class
S2(config)#line con 0
S2(config-line)#password cisco
S2(config-line)#login
S2(config-line)#exit
S2(config)# no ip domain-lookup
S2(config)#exit
S2#vlan database
S2(vlan)#vtp domain access
S2(vlan)#vtp password lab4
S2(vlan)#vtp client
S2(vlan)#exit
S2#conf t
S2(config)#int fa0/11
S2(config-if)#switchport access vlan 10
S2(config-if)#switchport mode access
S2(config-if)#switchport port-security
S2(config-if)#switchport port-security max 2
S2(config-if)#switchport port-security mac-address sticky
S2(config-if)#switchport port-security ciolation shutdown
S2(config-if)#no shut
S2(config-if)#int fa0/18
S2(config-if)#switchport access vlan 20
S2(config-if)#switchport mode access
S2(config-if)#switchport port-security
S2(config-if)#switchport port-security max 2
S2(config-if)#switchport port-security mac-address sticky
S2(config-if)#switchport port-security ciolation shutdown
S2(config-if)#no shut
S2(config-if)#int fa0/6
S2(config-if)#switchport access vlan 30
S2(config-if)#switchport mode access
S2(config-if)#switchport port-security
S2(config-if)#switchport port-security max 2
S2(config-if)#switchport port-security mac-address sticky
S2(config-if)#switchport port-security ciolation shutdown
S2(config-if)#no shut
S2(config-if)#int vlan 99
S2(config-if)#ip address 172.17.99.12 255.255.255.0
S2(config-if)#
S2(config-if)#int fa0/1
S2(config-if)#switchport trunk native vlan 99
S2(config-if)#switchport mode trunk
S2(config-if)#no shut
S2(config-if)#int fa0/2
S2(config-if)#switchport trunk native vlan 99
S2(config-if)#switchport mode trunk
S2(config-if)#no shut
S2(config-if)#int fa0/3
S2(config-if)#switchport trunk native vlan 99
S2(config-if)#switchport mode trunk
S2(config-if)#no shut
S2(config-if)#int fa0/4
S2(config-if)#switchport trunk native vlan 99
S2(config-if)#switchport mode trunk
S2(config-if)#no shut
S2(config-if)#int fa0/5
S2(config-if)#switchport trunk native vlan 99
S2(config-if)#switchport mode trunk
S2(config-if)#no shut

S3
Switch>en
Switch#conf t
Switch(config)#hostname S3
S3(config)#vlan 99
S3(config-vlan)#name management
S3(config-vlan)#vlan 10
S3(config-vlan)#name engineering
S3(config-vlan)#vlan 20
S3(config-vlan)#name sales
S3(config-vlan)#vlan 30
S3(config-vlan)#name administration
S3(config-vlan)#exit
S3(config)#enable secret class
S3(config)#line con 0
S3(config-line)#password cisco
S3(config-line)#login
S3(config-line)#exit
S3(config)# no ip domain-lookup
S3(config)#exit
S3#vlan database
S3(vlan)#vtp domain access
S3(vlan)#vtp password lab4
S3(vlan)#vtp client
S3(vlan)#exit
S3#conf t
S3(config)#int fa0/11
S3(config-if)#switchport access vlan 10
S3(config-if)#switchport mode access
S3(config-if)#switchport port-security
S3(config-if)#switchport port-security max 2
S3(config-if)#switchport port-security mac-address sticky
S3(config-if)#switchport port-security ciolation shutdown
S3(config-if)#no shut
S3(config-if)#int fa0/18
S3(config-if)#switchport access vlan 20
S3(config-if)#switchport mode access
S3(config-if)#switchport port-security
S3(config-if)#switchport port-security max 2
S3(config-if)#switchport port-security mac-address sticky
S3(config-if)#switchport port-security ciolation shutdown
S3(config-if)#no shut
S3(config-if)#int fa0/6
S3(config-if)#switchport access vlan 30
S3(config-if)#switchport mode access
S3(config-if)#switchport port-security
S3(config-if)#switchport port-security max 2
S3(config-if)#switchport port-security mac-address sticky
S3(config-if)#switchport port-security ciolation shutdown
S3(config-if)#no shut
S3(config-if)#int vlan 99
S3(config-if)#ip address 172.17.99.13 255.255.255.0
S3(config-if)#
S3(config-if)#int fa0/1
S3(config-if)#switchport trunk native vlan 99
S3(config-if)#switchport mode trunk
S3(config-if)#no shut
S3(config-if)#int fa0/2
S3(config-if)#switchport trunk native vlan 99
S3(config-if)#switchport mode trunk
S3(config-if)#no shut
S3(config-if)#int fa0/3
S3(config-if)#switchport trunk native vlan 99
S3(config-if)#switchport mode trunk
S3(config-if)#no shut
S3(config-if)#int fa0/4
S3(config-if)#switchport trunk native vlan 99
S3(config-if)#switchport mode trunk
S3(config-if)#no shut
S3(config-if)#int fa0/5
S3(config-if)#switchport trunk native vlan 99
S3(config-if)#switchport mode trunk
S3(config-if)#no shut

100%